LCHW 3OC
Smart Surge Protection with Total RV Electrical Protection

Download the LCHW 30C Manual:
Features:
High/Low Voltage Protection: Whenever source power falls below 104 volts, or rises above 132 volts the EMS automatically shuts down power to the RV. Once the AC power source raises above 104 volts or below the 132 volt level the time delay indicator flashes for the preset time and then automatically restores power to the RV.
Time Delay for Air Conditioner Compressor: Whenever power is interrupted by the source or the EMS due to a fault condition, the built in time delay is activated. There are two settings on the EMS. One is 136 seconds, and the other is 15 seconds. Consult your air conditioner manual to see if it has a time delay built into it. If so use the 15 second delay if not use the 136 second delay.
Three mode surge protection: This feature provides full surge protection L-N, L-G, and N-G. Total joule rating is 1820, response time of <1 nano second.
Surge Indicator: In the unlikely event a power surge damages the surge protector circuit within the EMS (L-N, or L-G) the digital display error code will read E-10. This is your indication that the surge part of the EMS needs to be replaced.
Reverse Polarity Protection: If source power has reverse polarity the EMS will not allow power to the RV and the error code will read E1.
Open Neutral Protection: If the source has an open neutral the display will not light, and the EMS will not allow power to the RV.
Open Ground Protection: If source power has an open ground the EMS will not allow power to the RV and the error code will read E2.
AC Frequency Protection: If the source power frequency deviates + or - 9 hertz from 60 cycles per second the EMS will shut power down and the error code will read E7 or E8.
Accidental 220V Protection: If 220 volts is detected when plugging into source power the EMS will not allow power to the RV and the EMS will not be hurt. If this condition occurs while power is applied to the RV, the EMS shuts off power instantly. In either case the display will read the HHH for high voltage and E3 will be displayed for the error code.
Integrated Information Display: The display continuously scrolls all of the power source information. E-0 (correct electricity) or E 1-10 (errors explained later) Voltage, Current (amps), Frequency, and Previous Error. Each reading is displayed for 2 seconds.
Previous Error Code (PE): This feature tells the user why the EMS previously interrupted power to the RV. This is only displayed if an error actually occurs. PE is erased from memory when power is disconnected to the EMS.
Bypass: The enclosed blue jumper wire allows the user to bypass the computer circuit in the EMS in the event of computer board failure. This allows source power into the RV. This does not disable the surge protection portion of the EMS.
Modular Design: Parts are designed for simple plug and play replacement, making repairs extremely user friendly
Microprocessor Controlled: The computer and remote display are driven by state of the art microprocessors that are programmed with software to drive the entire EMS. Should this software ever be changed EMS owners can receive a free upgraded processor with return of the old.
Hardwired: Semi permanent Three Year Warranty - 9-1/2"L x 5"W x 3-1/2"D
VIP Enterprises & Progressive Industries are committed to making your RV experience easier and safer.
[back to top]
HW 5OC
Smart Surge Protection with Total RV Electrical Protection
Download the HW 50C Manual:
Features:
High/Low Voltage Protection: Whenever source power falls below 104 volts, or rises above 132 volts the EMS automatically shuts down power to the RV. Once the AC power source raises above 104 volts or below the 132 volt level the time delay indicator flashes for the preset time and then automatically restores power to the RV.
Time Delay for Air Conditioner Compressor: Whenever power is interrupted by the source or the EMS due to a fault condition, the built in time delay is activated. There are two settings on the EMS. One is 136 seconds, and the other is 15 seconds. Consult your air conditioner manual to see if it has a time delay built into it. If so use the 15 second delay if not use the 136 second delay.
Five mode surge protection: This feature provides full surge protection L-N, L-N, L-G, L-G, L-L, and N-G. Total joule rating is 3640, response time of <1 nano second.
Surge Indicator: In the unlikely event a power surge damages the surge protector circuit within the EMS (L-N, or L-G) the digital display error code will read E-10. This is your indication that the surge part of the EMS needs to be replaced.
Reverse Polarity Protection: If source power has reverse polarity the EMS will not allow power to the RV and the error code will read E1.
Open Neutral Protection: If the source has an open neutral the display will not light, and the EMS will not allow power to the RV.
Open Ground Protection: If source power has an open ground the EMS will not allow power to the RV and the error code will read E2.
AC Frequency Protection: If the source power frequency deviates + or - 9 hertz from 60 cycles per second the EMS will shut power down and the error code will read E7 or E8.
Accidental 220V Protection: If 220 volts is detected when plugging into source power the EMS will not allow power to the RV and the EMS will not be hurt. If this condition occurs while power is applied to the RV, the EMS shuts off power instantly. In either case the display will read the voltage and E3 or E5 will be displayed depending on the error.
Remote Information Display: The display continuously scrolls all of the power source information. E-0 (correct electricity) or E 1-10 (errors explained later) Voltage Line-1, Current L-1 (amps), Voltage Line-2, Current L-2 (amps), Frequency, and Previous Error. Each reading is displayed for 2 seconds.
Previous Error Code (PE): This feature tells the user why the EMS previously interrupted power to the RV. This is only displayed if an error actually occurs. PE is erased from memory when power is disconnected to the EMS.
Bypass Switch: This switch is located on the remote display. Switching to OFF allows the user to bypass the computer circuit in the EMS in the event of computer board failure. This allows source power into the RV. This does not disable the surge protection portion of the EMS.
Modular Design: Parts are designed for simple plug and play replacement, making repairs extremely user friendly.
Microprocessor Controlled: The computer and remote display are driven by state of the art microprocessors that are programmed with software to drive the entire EMS. Should this software ever be changed EMS owners can receive a free upgraded processor with return of the old.
Hardwired: Semi permanent - Three Year Warranty - 9-1/2"L x 5"W x 4-1/2"D
VIP Enterprises & Progressive Industries are committed to making your RV experience easier and safer.
[back to top]
HW 3OC
Smart Surge Protection with Total RV Electrical Protection
Download the HW 30C Manual:
Features:
High/Low Voltage Protection: Whenever source power falls below 104 volts, or rises above 132 volts the EMS automatically shuts down power to the RV. Once the AC power source raises above 104 volts or below the 132 volt level the time delay indicator flashes for the preset time and then automatically restores power to the RV.
Time Delay for Air Conditioner Compressor: Whenever power is interrupted by the source or the EMS due to a fault condition, the built in time delay is activated. There are two settings on the EMS. One is 136 seconds, and the other is 15 seconds. Consult your air conditioner manual to see if it has a time delay built into it. If so use the 15 second delay if not use the 136 second delay.
Three mode surge protection: This feature provides full surge protection L-N, L-G, and N-G. Total joule rating is 1820, response time of <1 nano second.
Surge Indicator: In the unlikely event a power surge damages the surge protector circuit within the EMS (L-N, or L-G) the digital display error code will read E-10. This is your indication that the surge part of the EMS needs to be replaced.
Reverse Polarity Protection: If source power has reverse polarity the EMS will not allow power to the RV and the error code will read E1.
Open Neutral Protection: If the source has an open neutral the display will not light, and the EMS will not allow power to the RV.
Open Ground Protection: If source power has an open ground the EMS will not allow power to the RV and the error code will read E2.
AC Frequency Protection: If the source power frequency deviates + or - 9 hertz from 60 cycles per second the EMS will shut power down and the error code will read E7 or E8.
Accidental 220V Protection: If 220 volts is detected when plugging into source power the EMS will not allow power to the RV and the EMS will not be hurt. If this condition occurs while power is applied to the RV, the EMS shuts off power instantly. In either case the display will read the voltage and E3 or E5 will be displayed depending on the error.
Remote Information Display: The display continuously scrolls all of the power source information. E-0 (correct electricity) or E 1-10 (errors explained later) Voltage, Current (amps), Frequency, and Previous Error. Each reading is displayed for 2 seconds.
Previous Error Code (PE): This feature tells the user why the EMS previously interrupted power to the RV. This is only displayed if an error actually occurs. PE is erased from memory when power is disconnected to the EMS.
Bypass Switch: This switch is located on the remote display. Switching to OFF allows the user to bypass the computer circuit in the EMS in the event of computer board failure. This allows source power into the RV. This does not disable the surge protection portion of the EMS.
Modular Design: Parts are designed for simple plug and play replacement, making repairs extremely user friendly.
Microprocessor Controlled: The computer and remote display are driven by state of the art microprocessors that are programmed with software to drive the entire EMS. Should this software ever be changed EMS owners can receive a free upgraded processor with return of the old.
Hardwired: Semi permanent - Three Year Warranty - 9-1/2"L x 5"W x 3-1/4"D
VIP Enterprises & Progressive Industries are committed to making your RV experience easier and safer.
[back to top]
PT 5OC
Smart Surge Protection with Total RV Electrical Protection
Download the PT 50C Manual:
Features:
High Low Voltage Protection: Whenever source power falls below 104 volts, or it rises above 132 volts the EMS automatically shuts down power to the RV. Once the source power rises above 104-volts, or falls below the 132-volt level the time delay indicator flashes for the preset time and then automatically restores power to the RV.
Time Delay for A/C Compressor: Whenever source power is interrupted (by the source or the EMS), due to a fault condition, the built in time delay is activated for 136 seconds. This prevents the air conditioners from trying to start up under load. Starting up under load will burn up air conditioners.
4-Mode Surge Protection: This feature provides full surge protection L-N, L- N, L-G, L-G, L-L and N-G. Joule rating is 3640, with a response time of <1 nano second.
Surge Indicator: In the unlikely event a power surge damages the surge protector circuit within the EMS, L-N, or L-G, the digital display error code will read E-l0. This is your indication that the surge part of the EMS needs to be replaced.
Reverse Polarity Protection: If source power has a reverse polarity condition, the EMS will not allow power to the RV and the error code will read E1.
Open Neutral Protection: If the source power has an open neutral condition the display will not light, and will not allow power to the RV.
Open Ground Protection: If source power has an open ground condition the EMS will read an error code of E2 and will not allow power to the RV.
AC Frequency Protection: If source power frequency deviates +/- 9 hertz from 60 cycles per second the EMS will shut down source power, and indicate an E7 or E8 error code on the digital display.
Accidental 220V Protection: If 220 volts is detected when plugging into source power the EMS will not allow power to the RV. If this condition occurs while power is applied to the RV, the EMS shuts off power instantly. The display will read the voltage, and the appropriate error code.
Remote Information Display: Scrolls continuously all of the power source information, voltage, current, frequency, error codes, and previous errors. Each reading is displayed for 2 seconds.
Previous Error Code (PE): This feature tells the user why the EMS previously interrupted power to the RV. This is only displayed if an error actually occurs and is erased from memory when power is disconnected.
Weather Resistant: Can be exposed to elements but may not be submerged.
Microprocessor Controlled: The computer is driven by state of the art microprocessors that are programmed with software to drive the entire EMS.
Built in Lock Bracket: This bracket allows the user to secure the EMS to the power source to help prevent theft.
Portable One Year Warranty - 5"W x 8-1/2"H (plus 8" cord/total 16-1/2"H) x 4-1/2"D
VIP Enterprises & Progressive Industries are committed to making your RV experience easier and safer.
[back to top]
PT 3OC
Smart Surge Protection with Total RV Electrical Protection
Download the PT 30C Manual:
Features:
High/Low Voltage Protection: Whenever source power falls below 104 volts, or it rises above 132 volts the EMS automatically shuts down power to the RV. Once the source power rises above 104-volts, or falls below the 132-volt level the time delay indicator flashes for the preset time and then automatically restores power to the RV.
Time Delay for Air Conditioner Compressor: Whenever source power is interrupted (by the source or the EMS), due to a fault condition, the built in time delay is activated for 136 seconds. This prevents the air conditioners from trying to start up under load. Starting up under load will burn up air conditioners.
Three mode surge protection: This feature provides full surge protection L-N, L-G, and N-G. Joule rating is 1780, with a response time of <1 nano second.
Surge Indicator: In the unlikely event a power surge damages the surge protector circuit within the EMS, L-N, or L-G, the digital display error code will read E-l0. This is your indication that the surge part of the EMS needs to be replaced.
Reverse Polarity Protection: If source power has a reverse polarity condition, the EMS will not allow power to the RV and the error code will read E1.
Open Neutral Protection: If the source power has an open neutral condition the display will not light, and will not allow power to the RV.
Open Ground Protection: If source power has an open ground condition the EMS will read an error code of E2 and will not allow power to the RV.
AC Frequency Protection: If source power frequency deviates +/- 9 hertz from 60 cycles per second the EMS will shut down source power, and indicate an E7 or E8 error code on the digital display.
Accidental 220V Protection: If 220 volts is detected when plugging into source power the EMS will not allow power to the RV. If this condition occurs while power is applied to the RV, the EMS shuts off power instantly. The display will read the voltage, and the appropriate error code.
Integrated Information Panel: Scrolls continuously all of the power source information, voltage, current, frequency, error codes, and previous errors. Each reading is displayed for 2 seconds
Previous Error Code: This feature tells the user why the EMS previously interrupted power to the RV. This is only displayed if an error actually occurs and is erased from memory when power is disconnected.
Weather Resistant: Can be exposed to elements but may not be submerged.
Microprocessor Controlled: The computer is driven by state of the art microprocessors that are programmed with software to drive the entire EMS.
Built in Lock Bracket: This bracket allows the user to secure the EMS to the power source to help prevent theft.
Portable - One Year Warranty - 5"W x 8-1/2"H (plus 8" cord/total 16-1/2"H) x 3-1/2"D
VIP Enterprises & Progressive Industries are committed to making your RV experience easier and safer.
[back to top]
RDK- Remote Display Kit
RDK Remote Display Kit allows an existing EMS HW series owner to add an additional digital remote display to their system. Simple plug in operation makes it a very easy to understand and install kit. System includes one digital remote display, one switch box, one 3 foot data cable and one 14 foot data cable. The RDK comes with a 3 year warranty.
Instructions
1.Disconnect existing display from EMS and connect it to the switch box input.
2.Connect the three foot cable to a switch box outlet and existing (mounted) display.
3.Connect new 14 foot cable to the other switch box outlet. Route cable to desired location and connect to new display.
4.You can only read one display at a time. When the switch box is in one direction the corresponding display will light and the switch box LED will light.
Note: Only use enclosed data cable. Regular phone cable will not work.
[back to top]
Electric Protection Comparison Chart

Click here to enlarge
SSP 5O RV Smart Surge Protector
SSP 50 Smart Surge 240 Volt/50Amp is an inexpensive state of the art way to protect your RV from surges. Plus it comes with built in dual line polarity tester to check the power source for proper wiring. It also has surge status indicators with fuse protection. This Smart Surge is sleek, compact, portable, weather resistant and requires no installation. It comes with a one year warranty.
Features - Specifications - Operation Guide - Warranty
Four Mode Surge Protection - Lines to Neutral, Lines to Ground, Neutral to Ground and Line to Line. The SSP50 is rated for 240 Volts/50 Amps with 900 joules and 39,000 surge amps. It has less than one nano second response time.
Circuit Tester checks for - Reverse Polarity Open Ground Open Neutral - on both lines
#1 Red light On & #2 Red light Off = Correct Wiring Safe for you and equipment
#1 Red light Off & #2 Red light On = Reverse Polarity Bad for sensitive equipment
#1 Red light On & #2 Red light On = Open Neutral No power
#1 Red light Off & #2 Red light Off = Open Ground Could result in fatal shock
Green Surge Light on = Good surge protection Green light off = Surge protection bad
Size - 12" H (includes cord) x 4 1/2" W x 3 1/2" D
Operating Instructions:
1. It is important to check the power source receptacle for any charring or discoloration. This indicates there is a poor electrical contact. If you plug into it you could damage the Smart Surge plug. Always turn the source power off prior to plugging in the Smart Surge. This will reduce the risk of arcing and electrical shock.
2. Plug Smart Surge into source power prior to plugging in RV
3. Verify red indicator lights are lit to reflect source power is wired correctly (Line1 & Line 2)
4. Verify green surge indicators are lit
5. Plug RV into Smart Surge ONLY if the source power is wired correctly and surge light is illuminated, both Line 1 and L 2
Warranty:
Progressive warrants its products are free from defects in materials and workmanship for a period of one year. This is in lieu of all other warranties, obligations, or liabilities expressed by the company. In the event that a properly installed EMS proves defective under normal use, Progressive will repair or replace the device at its discretion.
For technical support call 919-462-8280.
Progressive cannot assume responsibility for acts of god, alterations, shipping handling or any other factors not under the control of Progressive Industries.
Progressive has no responsibility for installation, personal injury, property damage, incidental, contingent, or consequential damages of any kind resulting from defects or failure of the unit to function.
The remedy for breach of this warranty is limited to the repair or replacement of the defective product at Progressives option. In no case shall the liability prescribed by law exceed the purchase price. Some states do not allow exclusion or limitation of incidental or consequential damages or allow disclaimer, modifications, or limitations on how long a warranty lasts, therefore the above warranties may not apply to you. This warranty gives you certain legal rights, and you may have other rights, which may vary from state to state.
[back to top]
SSP 3O
RV Smart Surge Protector
SSP 30 Smart Surge 120 Volt/30Amp is an inexpensive state of the art way to protect your RV from surges. Plus it comes with built in polarity tester to check the power source for proper wiring. It also has a surge status indicator with fuse protection. This Smart Surge is sleek, compact, portable, weather resistant and requires no installation. It comes with a one year warranty.
Features - Specifications - Operation Guide - Warranty
Three Mode Surge Protection - Line to Neutral, Line to Ground and Neutral to Ground. The SSP30 is rated for 120 Volts/30 Amps with 450 joules and 19,500 surge amp. It has less than one nano second response time.
Circuit Tester checks for - Reverse Polarity Open Ground Open Neutral
#1 Red light On & #2 Red light Off = Correct Wiring Safe for you and equipment
#1 Red light Off & #2 Red light On = Reverse Polarity Bad for sensitive equipment
#1 Red light On & #2 Red light On = Open Neutral No power
#1 Red light Off & #2 Red light Off = Open Ground Could result in fatal shock
Green Surge Light on = Good surge protection Green light off = Surge protection bad
Size - 12" H (includes cord) x 3" W x 2 1/2" D
Operating Instructions:
1. It is important to check the power source receptacle for any charring or discoloration. This indicates there is a poor electrical contact. If you plug into it you could damage the Smart Surge plug. Always turn the source power off prior to plugging in the Smart Surge. This will reduce the risk of arcing and electrical shock.
2. Plug Smart Surge into source power prior to plugging in RV
3. Verify red indicator lights are lit to reflect source power is wired correctly
4. Verify green surge indicator is lit
5. Plug RV into Smart Surge ONLY if the source power is wired correctly and surge light is illuminated.
Warranty:
Progressive warrants its products are free from defects in materials and workmanship for a period of one year. This is in lieu of all other warranties, obligations, or liabilities expressed by the company. In the event that a properly installed EMS proves defective under normal use, Progressive will repair or replace the device at its discretion.
For technical support call 919-462-8280.
Progressive cannot assume responsibility for acts of god, alterations, shipping handling or any other factors not under the control of Progressive Industries.
Progressive has no responsibility for installation, personal injury, property damage, incidental, contingent, or consequential damages of any kind resulting from defects or failure of the unit to function.
The remedy for breach of this warranty is limited to the repair or replacement of the defective product at Progressives option. In no case shall the liability prescribed by law exceed the purchase price. Some states do not allow exclusion or limitation of incidental or consequential damages or allow disclaimer, modifications, or limitations on how long a warranty lasts, therefore the above warranties may not apply to you. This warranty gives you certain legal rights, and you may have other rights, which may vary from state to state.
[back to top]
Adapters and Connectors
A 50/30
RV Smart Surge Protector
A 50/30 50 Amp Female to 30 Amp Male Compact Adapter provides superior durability and heat resistance over dog bone type adapters. Uses high impact, heat resistant ABS plastic casing. The adapter has heavy duty highly conductive medal parts which greatly improve heat dissipation and conductivity. Its solid ground pin provides improved ground connection for safety. The molded finger grips make it easier to disconnect after use. Plus, unlike dog-bone type adapters, no cable is used therefore eliminating cable separation. It comes with a one year warranty.
Size - 2_" H x 2_" W x 2" D
|